15 research outputs found

    design of passive ring resonators to be used for sensing applications

    Get PDF
    In this paper we report on the effects of two optical beams counterpropagating in a passive ring resonator that is the building block of a lot of sensing applications. By using the transfer matrix method in combination with the coupled mode theory, the analytical expressions of the power transfer functions for drop and through port configurations are derived in both cases of single beam and double beams inside the ring. The implemented model has shown some improvements in the resonator performance, such as the increase of the transmission power and the reduction of the linewidth, when the interaction between the two beams is considered, with respect to the single beam ring resonator configuration

    Localized strain sensing with fiber Bragg-grating ring cavities

    Get PDF
    We report the theoretical description and the experimental demonstration of an optical resonator formed by inserting a Fiber Bragg Grating (FBG) in a closed fiber loop. The spectral characteristics of such a resonator strongly depend on the reflectivity of the FBG. In the wavelength region where the FBG reflectivity R is negligible, the system behaves like a conventional ring resonator. On the other hand, when R is not vanishing, a split-mode structure can be observed, associated to the degeneracy removal of two counterpropagating resonant modes. The magnitude of the mode splitting can be used to sense small variations of the FBG physical parameters, such as length, temperature or group index. An example of strain sensing with this setup is reported, showing that the mode splitting is sensitive to a mechanical strain applied to the FBG, while it is almost insensitive to a strain applied to any other point of the resonator. This peculiar feature allows to perform cavity-enhanced, local strain measurements with a reduced sensitivity to environmental perturbations, which represents an important improvement in the framework of the fiber-optic sensors. (C)2013 Optical Society of Americ

    Investigation of refractive index sensing based on Fano resonance in fiber Bragg grating ring resonators.

    Get PDF
    In this paper we theoretically investigate a ring resonant cavity obtained by closing on itself a pi-shifted fiber Bragg grating, to be used for refractive index sensing applications. Differently from a conventional pi-shifted fiber Bragg grating, the spectral structure of this cavity is characterized by an asymmetric splitting doublet composed by a right side resonance having an asymmetric Fano profile and a left side resonance having a symmetric Lorentzian profile. The right side resonance shows a narrower and sharper peak than all the other kinds of resonance achievable with both conventional ring resonators and pi-shifted fiber Bragg gratings. A reduction of the resonant linewidth with respect to a conventional pi-shifted Fiber Bragg grating and a fiber ring resonator, having the same physical parameters, is theoretically proved, achieving up to five orders of magnitude improvement with respect to the usual ring resonator. Due to these resonance features, the pi-shifted Bragg grating ring resonator results suitable for RI sensing applications requiring extremely narrow resonances for high resolution measurements. In particular, by assuming a refractive index sensing to detect the presence of sugar in water, the sensor can show a theoretical resolution better than 10(-9) RIU. (C)2015 Optical Society of Americ

    Design and Optimization of Polarization Splitting and Rotating Devices in Silicon-on-Insulator Technology

    Get PDF
    We review polarization splitting and rotating photonic devices based on silicon-on-insulator technology platform, focusing on their performance and design criteria. In addition, we present a theoretical investigation and optimization of some rotator and splitter architectures to be employed for polarization diversity circuits. In this context, fabrication tolerances and their influences on device performance are theoretically estimated by rigorous simulations too

    Infected pancreatic necrosis: outcomes and clinical predictors of mortality. A post hoc analysis of the MANCTRA-1 international study

    Get PDF
    : The identification of high-risk patients in the early stages of infected pancreatic necrosis (IPN) is critical, because it could help the clinicians to adopt more effective management strategies. We conducted a post hoc analysis of the MANCTRA-1 international study to assess the association between clinical risk factors and mortality among adult patients with IPN. Univariable and multivariable logistic regression models were used to identify prognostic factors of mortality. We identified 247 consecutive patients with IPN hospitalised between January 2019 and December 2020. History of uncontrolled arterial hypertension (p = 0.032; 95% CI 1.135-15.882; aOR 4.245), qSOFA (p = 0.005; 95% CI 1.359-5.879; aOR 2.828), renal failure (p = 0.022; 95% CI 1.138-5.442; aOR 2.489), and haemodynamic failure (p = 0.018; 95% CI 1.184-5.978; aOR 2.661), were identified as independent predictors of mortality in IPN patients. Cholangitis (p = 0.003; 95% CI 1.598-9.930; aOR 3.983), abdominal compartment syndrome (p = 0.032; 95% CI 1.090-6.967; aOR 2.735), and gastrointestinal/intra-abdominal bleeding (p = 0.009; 95% CI 1.286-5.712; aOR 2.710) were independently associated with the risk of mortality. Upfront open surgical necrosectomy was strongly associated with the risk of mortality (p < 0.001; 95% CI 1.912-7.442; aOR 3.772), whereas endoscopic drainage of pancreatic necrosis (p = 0.018; 95% CI 0.138-0.834; aOR 0.339) and enteral nutrition (p = 0.003; 95% CI 0.143-0.716; aOR 0.320) were found as protective factors. Organ failure, acute cholangitis, and upfront open surgical necrosectomy were the most significant predictors of mortality. Our study confirmed that, even in a subgroup of particularly ill patients such as those with IPN, upfront open surgery should be avoided as much as possible. Study protocol registered in ClinicalTrials.Gov (I.D. Number NCT04747990)

    Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)

    Get PDF
    In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. For example, a key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process versus those that measure fl ux through the autophagy pathway (i.e., the complete process including the amount and rate of cargo sequestered and degraded). In particular, a block in macroautophagy that results in autophagosome accumulation must be differentiated from stimuli that increase autophagic activity, defi ned as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (inmost higher eukaryotes and some protists such as Dictyostelium ) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the fi eld understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. It is worth emphasizing here that lysosomal digestion is a stage of autophagy and evaluating its competence is a crucial part of the evaluation of autophagic flux, or complete autophagy. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. Along these lines, because of the potential for pleiotropic effects due to blocking autophagy through genetic manipulation it is imperative to delete or knock down more than one autophagy-related gene. In addition, some individual Atg proteins, or groups of proteins, are involved in other cellular pathways so not all Atg proteins can be used as a specific marker for an autophagic process. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field

    Fibre Bragg Grating Based Strain Sensors: Review of Technology and Applications

    No full text
    Fibre Bragg grating (FBG) strain sensors are not only a very well-established research field, but they are also acquiring a bigger market share due to their sensitivity and low costs. In this paper we review FBG strain sensors with high focus on the underlying physical principles, the interrogation, and the read-out techniques. Particular emphasis is given to recent advances in highly-performing, single head FBG, a category FBG strain sensors belong to. Different sensing schemes are described, including FBG strain sensors based on mode splitting. Their operation principle and performance are reported and compared with the conventional architectures. In conclusion, some advanced applications and key sectors the global fibre-optic strain sensors market are envisaged, as well as the main market players acting in this field

    Positive and negative pull-back instabilities in mode splitting optomechanical devices

    No full text
    Optical gradient forces play an essential role in optomechanical systems. The systems based on coupled microresonators are of great importance for applications in signal processing, sensors, and actuators. Here, we theoretically and experimentally studied, for the first time, positive and negative pull-back instabilities originating from attractive and repulsive optical gradient forces, respectively, in an optomechanical device based on coupled microrings. The device consists of two coupled free-standing waveguides in two identical microrings, fabricated in the silicon-on-insulator process. The coupling between the two microrings results in the symmetric and antisymmetric resonances showing in the transmission spectrum of the device. By measuring the wavelength difference between the self-referenced symmetric and antisymmetric resonances, the wavelength tuning due to the optomechanical actuation is decoupled from the tuning due to the thermo-optical effect. It is demonstrated theoretically and experimentally that the positive pull-back instability originates from the attractive optical gradient force and the negative pull-back instability originates from the repulsive optical gradient force when the pump wavelength increases. The positive pull-back instability significantly increases the wavelength difference between the symmetric and antisymmetric resonances. On the contrary, the negative pull-back instability significantly decreases the wavelength difference

    Gyroscope Technology and Applications: A Review in the Industrial Perspective

    No full text
    This paper is an overview of current gyroscopes and their roles based on their applications. The considered gyroscopes include mechanical gyroscopes and optical gyroscopes at macro- and micro-scale. Particularly, gyroscope technologies commercially available, such as Mechanical Gyroscopes, silicon MEMS Gyroscopes, Ring Laser Gyroscopes (RLGs) and Fiber-Optic Gyroscopes (FOGs), are discussed. The main features of these gyroscopes and their technologies are linked to their performance

    Methane Gas Photonic Sensor Based on Resonant Coupled Cavities

    No full text
    In this paper we report methane gas photonic sensors exploiting the principle of absorption-induced redirection of light propagation in coupled resonant cavities. In particular, an example of implemented architecture consists of a Fabry–Pérot (FP) resonator coupled to a fibre ring resonator, operating in the near IR. By changing the concentration of the methane gas in the FP region, the absorption coefficient of the FP changes. In turn, the variation of the methane gas concentration allows the redirection of the light propagation in the fibre ring resonator. Then, the methane gas concentration can be evaluated by analysing the ratio between the powers of two resonant modes, counter-propagating in the fibre ring resonator. In this way, a self-referenced read-out scheme, immune to the power fluctuations of the source, has been conceived. Moreover, a sensitivity of 0.37 ± 0.04 [dB/%], defined as the ratio between resonant modes at different outputs, in a range of methane concentration included between the 0% and 5%, has been achieved. These results allow a detection limit below the lower explosive limit (LEL) to be reached with a cost-effective sensor system
    corecore